In Table 2 the number of faults and total time lost as a function of the system and kind of fault is presented together with the overall numbers for the previous two period (38 and 39).
Syst/Type | Soft | Elec | Optics | Mech | Others | Total | P39/P38 | |||||||
Telescope | 2 | 00:00 | 5 | 00:35 | 0 | 9 | 01:40 | 0 | 16 | 02:15 | 30/20 | 05:00/01:50 | ||
Building | 0 | 6 | 01:35 | 0 | 3 | 00:30 | 0 | 9 | 02:05 | 2/6 | 00:00/00:00 | |||
Computers | 11 | 00:20 | 3 | 00:10 | 0 | 0 | 3 | 00:00 | 17 | 00:30 | 12/16 | 00:55/00:45 | ||
ALFOSC | 11 | 00:50 | 3 | 00:00 | 1 | 00:00 | 0 | 0 | 15 | 00:50 | 14/16 | 01:00/00:50 | ||
MOSCA | 1 | 00:05 | 0 | 0 | 0 | 0 | 1 | 00:05 | 4/1 | 00:05/00:00 | ||||
NOTCam | 7 | 00:20 | 0 | 0 | 0 | 0 | 7 | 00:20 | 9/5 | 00:00/00:05 | ||||
StanCam | 5 | 00:45 | 0 | 0 | 0 | 1 | 00:00 | 6 | 00:45 | 8/3 | 00:45/00:20 | |||
FIES | 7 | 00:55 | 1 | 00:00 | 0 | 0 | 3 | 00:00 | 11 | 00:55 | 12/16 | 03:20/00:20 | ||
Others | 0 | 3 | 00:00 | 0 | 0 | 2 | 01:30 | 5 | 01:30 | 2/5 | 01:05/00:00 | |||
Total | 44 | 03:15 | 21 | 02:20 | 1 | 00:00 | 12 | 02:10 | 9 | 01:30 | 87 | 09:15 | 93/88 | 12:10/04:10 |
P39 | 49 | 05:50 | 30 | 04:40 | 2 | 00:00 | 8 | 01:35 | 4 | 00:05 | 93 | 12:10 | ||
P38 | 52 | 02:25 | 18 | 00:50 | 2 | 00:30 | 8 | 00:20 | 8 | 00:05 | 88 | 04:10 | ||
For each system-type category the total number of faults and total time lost are given |
Thomas Augusteijn 2010-05-27