General overview

In Table 2 the number of faults and total time lost as a function of the system and kind of fault is presented together with the overall numbers for the previous two periods (49 and 50).



Table 2: Down-time statistics for period 51$^a$
Syst/Type Soft Elec Optics Mech Others Total P50/P49
Telescope 2 00:50 9 00:20 2 00:00 3 04:10 3 08:50 19 14:10 8/14 10:50/01:45
Building 0   2 00:25 0   0   1 00:00 3 00:25 7/3 00:00/00:00
Computers 21 00:45 0   0   0   1 00:00 22 00:45 14/11 00:35/00:35
ALFOSC 26 01:15 3 00:00 0   2 03:00 0   31 04:15 39/23 00:45/01:40
MOSCA 1 00:00 0   0   0   1 00:00 2 00:00 0/3 00:00/00:00
NOTCam 8 00:50 4 00:00 0   2 00:00 1 00:20 15 01:10 10/2 00:15/00:00
StanCam 7 00:45 1 00:00 0   1 00:00 3 00:00 12 00:45 5/3 01:30/00:15
FIES 10 00:00 0   1 00:00 1 00:00 0   12 00:00 13/3 02:55/00:00
Others 3 00:00 0   0   0   4 00:00 7 00:00 5/6 00:00/00:10
Total 78 04:25 19 00:45 3 00:00 9 07:10 14 09:10 123 21:30 101/68 16:50/04:25
P50 74 06:05 8 00:00 1 00:00 11 09:15 7 01:30 101 16:50    
P49 43 02:45 12 00:40 1 00:15 6 00:30 6 00:15 68 04:25    
$^a$For each system-type category the total number of faults and total time lost are given

Thomas Augusteijn 2016-05-05