Search
Text Size:
Smaller Text Normal Text Larger Text

Facebook page

Twitter profile

YouTube channel

Overview of instrumentation


Facility instruments

  • ALFOSC - UV-optical imaging, polarimetry and low-resolution spectroscopy
  • NOTCam - NIR imaging and low-resolution spectroscopy
  • FIES - High-resolution, high-stability optical spectroscopy
  • StanCam - Standby CCD imager

Instrumentation with limited access

  • DIPol-UF - Three-band high-speed polarimeter
  • SOFIN - The Soviet-Finnish optical high-resolution spectrograph

To be retired after P71: instrument not applied for for more than 5 years

  • MOSCA: High-resolution, high-efficiency UV-optical imaging


Former instruments

  • LuckyCam - High resolution "Lucky" imaging in the visible
  • PolCor - The PolCor "Lucky" Polarimeter/coronagraph
  • SIRCA - The Stockholm InfraRed CAmera
  • TurPol: Photo-polarimeter

Instrument capabilities

Optical imaging
Instrument Detector Filters Scale (arcsec/pixel) Field-of-View Contact Comments
ALFOSC imaging E2V 2kx2k Various optical filters 0.214 6'.7 x 6'.7 TP also polarimetry
StanCam SITe 1kx1k Various optical filters 0.18 3'.0 x 3'.0 TP
MOSCA 2x2 mosaic of
2kx2k Loral
100mm diameter;
SDSS, UBVRI, Stromgren
0.11 7'.7 x 7'.7 TP
DIPol-UF Andor iXon Ultra 897 EM CCD cameras Three-channel BVR 0.12 1' x 1' in B,
0.7' x 0.7' in V and R
See here High-speed photometry; also polarimetry
DIPol-UF is not a common-user instrument, but is only supported during specific periods

Infrared imaging
Instrument Detector Filters Scale (arcsec/pixel) Field-of-View Contact Comments
NOTcam HAWAII 1kx1k HgCdTe NOTcam filters 0.23 (WFC) or
0.08 (HRC)
3'.9 x 3'.9 or
1'.4 x 1'.4
AD wavelength range:
1.0-2.5 micron;

Optical spectroscopy
Instrument Wavelength Range Dispersion (Å/pixel) Slit Length Detector Contact Comments
ALFOSC spectroscopy 3200-11000Å 0.26-13.7 for long slit
0.4 in echelle mode
5' for long slit
8" in echelle mode
E2V 2kx2k JT also spectropolarimetry;
also Multi Object (MOS) mode
FIES 3620-8980Å R=25000, 45000, 65000 Fiber-fed: 1.3" on sky, 2.5" for R=25000 CCD 15 JT Low-res (R=25000) wave range 3620-8580
Med-res (R=45000) wave range 3640-8840
High-res (R=65000) wave range 3640-8980
SOFIN 3200-10800Å R=80000 variable short slit Loral 2kx2k
EEV7
JT Only spectropolarimetry;
SOFIN is not a common-user instrument: only limited support is provided

Near-IR spectroscopy
Instrument Wavelength Range Dispersion (Å/pixel) Slit Length Detector Contact Comments
NOTCAM WFC low-res spectroscopy 'Z' J H K 4.1 in K
2.5 in J
4' HAWAII 1kx1k HgCdTe JT,AD R=2000 for WFC
NOTCAM HRC med-res spectroscopy 1.26-1.34 (Pa-beta)
1.57-1.67
2.07-2.20 (Br-gamma)
1.4 in K
0.8 in J
80'' HAWAII 1kx1k HgCdTe JT,AD R~5500 for HRC

Polarimetry
Instrument Filters Detector Scale (arcsec/pixel) Field of view Modes Contact Comments
ALFOSC FAPOL+ calcite Various optical filters E2V 2kx2k 0.21 140arcsec diameter linear and/or circular AD,TP also spectropolarimetry
ALFOSC polaroid Various optical filters E2V 2kx2k 0.21 7'.3 x 7'.3 linear AD,TP for extended targets
ALFOSC +WeDoWo Various optical filters E2V 2kx2k 0.21 linear AD,TP available from April 1, 2010
DIPol-UF Three-channel BVR Andor iXon Ultra 897 EM CCD cameras 0.12 1' x 1' in B,
0.7' x 0.7' in V and R
linear or circular See here High-speed polarimetry; also photometry
DIPol-UF is not a common-user instrument, but is only supported during specific periods

Instrument specialists:
AD: Anlaug Amanda Djupvik, TP: Tapio Pursimo, JT: John Telting. See here for contact information.

Back to top Last modified: October 14 2024